Thermal Latency adds to Lesion Depth after Application of High-Power Short-Duration Radiofrequency Energy : Results of a computer-modeling study

dc.contributor.authorIrastorza, Ramiro M.
dc.contributor.authorD'Avila, Andre
dc.contributor.authorBerjano, Enrique
dc.date.accessioned2026-11-17T19:30:09Z
dc.date.available2026-11-17T19:30:09Z
dc.date.issued2017-10-08
dc.description.abstractIntroduction: The use of ultra-short RF pulses could achieve greater lesion depth immediately after the application of the pulse due to thermal latency. Methods and results: A computer model of irrigated-catheter RF ablation was built to study the impact of thermal latency on the progress of the lesion depth created by short RF pulses. The computer results showed that the shorter the RF pulse duration (keeping energy constant), the greater the lesion depth during the cooling phase. For instance, after a 10-s pulse, lesion depth grew from 2.05 mm at the end of the pulse to 2.39 mm (17%), while after an ultra-short RF pulse of only 1 s the extra growth was 37% (from 2.22 mm to 3.05 mm). Importantly, short applications resulted in deeper lesions than long applications (3.05 mm vs. 2.39 mm, for 1- and 10-s pulse, respectively). While shortening in pulse duration allowed enlarging the lesion depth, the associated increase in applied voltage involved overheating in the tissue: temperatures around 100ºC were reached at 1 mm depth in the case of 1- and 5-s pulses. However, thanks to the enlarging of lesion depth during the cooling period (especially important with short pulses), it was possible to choose lower values of applied voltage for the case of short durations in order to obtain a lesion depth similar to that obtained with longer duration, and simultaneously avoid overheating. Conclusion: The thermal latency phenomenon seems to be the cause of significantly greater lesion depth after the application of short-duration high-power RF pulses. Results suggest that balancing the applied total energy when the parameters voltage and duration are changed is not the optimal strategy since overheating can occur in the case of short pulses.
dc.description.versionaceptadoaprobado
dc.format.extentpp. 322-327
dc.format.mimetypeapplication/pdf
dc.identifier.citationIrastorza, R. M., D'Avila, A. y Berjano, E. (2017). Thermal Latency adds to Lesion Depth after Application of High-Power Short-Duration Radiofrequency Energy : Results of a computer-modeling study. Journal Of Cardiovascular Electrophysiology, Vol. 29(2), 322-327. https://doi.org/10.1111/jce.13363
dc.identifier.otherhttp://hdl.handle.net/11336/63524
dc.identifier.urihttps://rid.unaj.edu.ar/handle/123456789/3754
dc.language.isoeng
dc.relation.ispartofJournal Of Cardiovascular Electrophysiology
dc.rights.accessrightsaccesoabierto
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/
dc.subjectCardiac ablation
dc.subjectComputer model
dc.subjectRF ablation
dc.subjectThermal latency
dc.titleThermal Latency adds to Lesion Depth after Application of High-Power Short-Duration Radiofrequency Energy : Results of a computer-modeling study
dc.typeArtículo Científico
unaj.author.affiliationIrastorza, Ramiro M. Consejo Nacional de Investigaciones Científicas y Técnicas. Instituto de Física de Líquidos y Sistemas Biológicos; Argentina.
unaj.author.affiliationIrastorza, Ramiro M. Universidad Nacional Arturo Jauretche. Instituto de Ingeniería y Agronomía; Argentina.
unaj.author.affiliationD'Avila, Andre. Hospital Cardiológico de Florianópolis; Brasil.
unaj.author.affiliationBerjano, Enrique. Universitat Politècnica de València. Department of Electronic Engineering. BioMIT; España.
unaj.issn.digital1540-8167
unaj.oai.snrdSi

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
RIDUNAJ-AC-20261117-Irastorza, R. M., D'Avila, A. y Berjano, E.pdf
Size:
1.8 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
308 B
Format:
Item-specific license agreed to upon submission
Description: